A living room filled with furniture and a fire place

Metal Fireplaces and Chase Tops in Carson, Fixed by Model Number

Book a Fireplace Check

Choose the job, add a line about the unit, and we phone back to set the visit.

Plate read firstPrices on paperParts by model
Data Plate Read First
Parts Ordered by Model
Photos With Each Report
Written Price Before Work
Based in Carson
Data Plate Read First
Parts Ordered by Model
Photos With Each Report
Written Price Before Work
Based in Carson
What Hamlin Does

Metal fireplaces lead the list in Carson.

Fireplace repair swaps worn panels and dampers for listed ones. The cap has to suit the pipe brand. The inspection reads the plate and checks it all. The other cards cover chase tops, masonry, gas units and stoves.

01

Chimney Sweep

Poly brushes sized to the metal pipe, the firebox panels vacuumed and the cap mesh cleared on the roof.

Poly heads matched to the pipe diameter
Refractory panels vacuumed, never scraped
Cap mesh opened and cleared
Open this job
02

Chimney Inspection

Data plate read first, then panels, pipe and chase top checked against what the maker lists.

Model and listing taken off the data plate
Level 1 visual check for $52
Level 2 camera run for $370
Open this job
03

Chimney Repair

Pulled-apart pipe sections, rusted chase tops and loose caps put right with the parts the system was built with.

Pipe sections reseated and locked
Rusted chase tops swapped for stainless
Masonry crowns sealed or recast
Open this job
04

Fireplace Inspection

Panels, doors, screens and air kit on a metal unit checked against the maker's own list of parts.

Data plate and model number recorded
Refractory panels checked for cracks and gaps
Steel firebox shell looked at behind the panels
Open this job
05

Fireplace Repair

Refractory panels, damper blades and screens swapped by model number, so the unit stays within its listing.

Refractory panels ordered by model number
Damper blades and handles freed or replaced
Missing doors and mesh screens sourced
Open this job
06

Chimney Level 2 Inspection

Camera through each pipe joint and the framing around the chase checked, written up for a sale or a quake.

Video of every pipe joint and section
Chase or attic spacing to framing checked
Data plate and listing recorded
Open this job
07

Chimney Cap Installation

The cap listed for your pipe brand, fitted with its collar, or a fastened stainless cap on a masonry flue.

Cap matched to pipe brand and size
Storm collar fitted under the cap
Stainless or copper on masonry flues
Open this job
08

Chimney Flashing Repair

Step flashing on a framed chase or counter flashing on brick, replaced where it has lifted or rusted.

Step flashing worked under chase siding
Counter flashing cut into brick joints
Failed metal replaced, not coated
Open this job
09

Chimney Masonry Repair

Worn joints repacked, flaked brick replaced and cracked crowns recast on the older brick stacks.

Worn joints ground out and repacked
Mortar mix suited to the brick
Flaked brick faces cut out
Open this job
10

Chimney Rebuilds

Brick taken down to sound masonry and rebuilt, or a rotted chase reframed around its listed pipe.

Brick rebuilt with steel tied to the house
Rotted chase framing replaced
New siding and chase top on reframed chases
Open this job
11

Fireplace Cleaning

Soft refractory panels vacuumed, doors and screens cleaned and the damper worked free.

Panels vacuumed with a soft brush
Ash removed in a metal can
Glass doors and mesh cleaned
Open this job
12

Gas Fireplace Cleaning

Burner, pilot and logs cleaned to the maker's diagram, glass haze cleared and the outside vent checked.

Glass removed and its haze cleared
Burner ports and pilot hood cleaned
Logs set back on the maker's diagram
Open this job
13

Gas Fireplace Repair

Pilot, valve, sensor and receiver tested in order, and the failed part replaced with one made for the model.

Pilot and flame sensor tested first
Valve and generator output measured
Receivers and wall switches checked
Open this job
14

Fireplace Remodel

A new surround and mantel laid out to the spacing in the fireplace manual before any tile is picked.

Spacing taken from the unit's manual
Tile, stone or plaster faces
Mantel height set to the listing
Open this job
15

Fireplace Inserts

Checked against the old unit's listing first, then a gas insert set in with its own liner and cap.

Old unit checked for insert approval
Sealed gas insert behind glass
Own liner run to a new cap
Open this job
16

Pellet Stove Repair

Vent pipe and burn pot cleaned first, then igniter, fans and auger tested against the maker's figures.

Vent pipe cleaned end to end
Burn pot and heat exchanger cleared
Igniter and fans tested
Open this job
17

Wood Stove Repair

Gaskets, glass and baffles renewed, and stovepipe spacing checked against the label on the stove.

Door and glass gaskets replaced
Cracked glass swapped
Baffles and burn tubes renewed
Open this job
18

Gas Logs

A log set the fireplace manual allows, with the damper clamped open and every gas joint tested.

Manual checked for allowed log sets
Damper clamped partly open
Burner set and gas connected
Open this job
19

Chimney Seismic Retrofit

Bracing, straps or a rebuild to the roofline for a brick stack, each priced in writing after a look.

Stack and its ties to the house checked
Steel bracing back to the roof
Straps tied into the framing
Open this job
20

Chimney Crown Repair

Hairline cracks sealed or a broken crown recast with an overhang, priced once we have seen the top.

Fine cracks closed with elastic sealer
Broken crowns cut off and recast
Overhang formed on new crowns
Open this job
21

Dryer Vent Cleaning

Duct brushed and blown out, the outside hood and flap cleared, and airflow checked once the dryer runs.

Rotary brush run through the duct
Outside hood and flap cleared
Crushed or loose sections found
Open this job
22

Chimney Liner Installation

A stainless liner sized to the appliance, run top to bottom and capped, after a camera look at the flue.

Camera look before sizing
Stainless liner sized to the appliance
Insulation where spacing calls for it
Open this job
23

Chimney Leak Repair

The stain traced back to the chase top, collar, siding or flashing, and that spot fixed.

Water traced from stain to entry
Chase tops and storm collars checked
Siding seams and flashing tested
Open this job
24

Chimney Waterproofing

A breathable repellent on sound brick, applied after the crown and joints have been put right.

Crown and joints fixed first
Brick cleaned before treatment
Repellent that lets vapor out
Open this job
25

Chimney Damper Repair

Damper blades freed or replaced with the maker's part, or a top-mounted damper fitted on a masonry flue.

Stuck blades freed and tested
Warped blades replaced by model
Handles, chains and pivots repaired
Open this job
26

Chimney Chase Cover

A stainless cover with a raised center and folded edges, fitted with a fresh collar under the cap.

Chase measured for a made-to-size cover
Stainless with a raised center
Folded edges over the siding
Open this job
Out From Carson

Gardena, Long Beach and Bellflower first, then the rest of the list.

Each town page says what kind of chimney we tend to find on its streets and what we check first there.

The Hamlin Route

140

Town pages on this site

Plate First

On every fireplace we open

Carson

Where the truck sets out

Open a town to see the chimneys we find there and what gets checked first.

Carson Fireplace Questions

What tract house owners ask about their fireplaces

Data plates, cracked panels, rusted chase tops and the inspection a sale calls for.

Where does Hamlin Chimney Services work from?

Carson is home, and most days run out to Gardena, Long Beach and Bellflower and the nearby Los Angeles County towns on our area list. Put your ZIP code in the form and the reply tells you whether you are on the route and which visit fits the house.

How do I know if my fireplace is factory-built?

Open the doors or screen and look along the side or top of the opening for a metal tag. That data plate names the maker and model. Other clues: thin panels in place of firebrick, a metal frame around the opening, and a boxed wood chase outside rather than brick. We confirm it on the first visit.

Why can't a crack in a metal fireplace just be patched with mortar?

A prefab fireplace was tested by its maker as a complete set of parts, and that listing is what makes it safe at the spacing it sits at. Mortar, cut firebrick or a part from another brand takes it outside that listing. We order replacement panels and parts by the model number on the plate.

What does a chase cover do, and why does mine leak?

It is the metal lid on top of a framed chimney. Builders often used galvanized sheet, which rusts and sags so rain pools around the pipe and runs down inside the chase. A stainless cover with a raised center and a new storm collar under the cap stops that. We measure the top before pricing it.

What does a cap cost?

Installed, a cap is quoted on site. The simplest job is a stock cap on a single masonry flue; the biggest job is a larger or made-to-measure cap. On a metal chimney the cap has to be one listed for that pipe brand and size, which is often why the figure differs from a hardware store price.

Is my old prefab fireplace past its useful life?

It can be. Signs we look for are steel behind the panels that has burned through or warped, pipe sections that have separated, and parts no longer made for that model. When repair stops being sensible, we price a replacement unit or a gas insert, if the box allows one, side by side.

Which inspection does a house sale need?

NFPA 211 points to a Level 2 when a property is sold, and on a prefab system that is where the camera earns its keep: it shows joints between pipe sections and the spacing to framing. Ours is $370. The written report goes to the person who booked it, and to the agent if you ask.

What if the house has more than one fireplace?

Each one is its own system with its own pipe, cap and data plate, even when two share a chase. We check and price them one by one on the same visit, so the report lists each fireplace by room and you can choose which to fix first.

Can I burn wood on a no-burn day?

Not in Carson and most of the county. The South Coast AQMD Rule 445 bans wood burning in fireplaces and stoves on days it calls a no-burn alert, usually in the cooler months. A gas fireplace, or a gas insert where the old unit allows one, can still be used on those days.

Our gas fireplace pilot keeps going out. Is that a big job?

Usually one part has failed: the flame sensor, a dirty pilot, the valve, or a vent that trips the shutoff. Testing in order tells us which, and the fix is the part made for that model. We say what failed before fitting anything and price it first.

Do I still need a carbon monoxide alarm with a sealed gas unit?

Yes. California asks for CO alarms in homes with a fuel-burning appliance or an attached garage. A sealed unit vents outside, but a crushed or blocked pipe can change that without any smell. Fit one on every level and outside the bedrooms, and we check the vent run on every gas visit.

Do you price masonry and flashing work before you start?

Always in writing, after we have seen it. Brick, crown and flashing jobs vary with height, roof type and how far the damage goes, so a phone figure would be a guess. Cricket work is the exception with a set range: $420 to $945 on its own, or $630 to $1,600 with new flashing.

Not seeing your question?

Call (323) 524-3947
A Hamlin Visit, Plate to Paper

From the firebox tag to the parts order

Five steps, in the order the crew takes them, whether the job is a panel swap or a Level 2.

1
1

Describe the Fireplace

Use the form, or call. Tell us whether there is a metal tag inside the opening, what the outside chimney looks like, and what made you get in touch.

2
2

We Pick the Visit

From what you describe we suggest a sweep, a Level 1, a Level 2 or a repair look, with its price where one is set. We may ask for a photo when we call back.

3
3

Plate and Parts Checked

On site the crew reads the data plate, then works through panels, damper, pipe and chase top against that model. Masonry gets its own checks.

4
4

Report With Photos

You receive photos of each finding and a written note naming the parts by model, with any repair priced line by line on a separate sheet.

5
5

Parts Ordered, Work Booked

Once you choose what to fix, we order the listed parts and book the work. Finished repairs are photographed and added to your file.

Built-In Fireplaces

Get the Carson prefab unit back to its listing.

Plate
Model and maker noted
Panels
Cracks and gaps found
Cover
Rust on the chase top
Cap
Listed for the pipe
(323) 524-3947

Which fireplace is giving trouble?

Name, number and the job. We phone back to set the visit.

By sending, you agree Hamlin Chimney Services may contact you by call, automated text or email about your request. Consent isn't required to buy. Msg & data rates may apply; reply STOP to opt out. Privacy Policy

Why Hamlin Starts at the Data Plate

The model number tells us which parts belong, so the repair fits the unit.

Hamlin Chimney Services is based in Carson and works the tract streets around it, out to Gardena, Long Beach and Bellflower. Many of those houses were built with a metal fireplace and a framed wood chase rather than a brick chimney.

A unit like that was tested by its maker as one set: firebox, panels, pipe, cap and chase cover, each at a set spacing from the wood around it. Fixing it with mortar or a part from another brand takes it off that listing, so we order by the model number on the plate.

Each finding is photographed and written up with the part name and model. You decide what is fixed now and what can wait, and nothing is ordered before you agree the price.

Carson
Where the Hamlin truck starts each day
Listed Parts
Ordered for the model on the plate
In Writing
Every price before any part is ordered
Model read off the firebox tag
Panels ordered for that model
Photos of each finding in the report
Price on paper before any order
a living room filled with furniture and a fire place
Tiled fireplace with a white wood mantel in a red living room

Listing Before Labor

A metal fireplace is safe as the set its maker tested. We read the plate and repair to it, so every part we fit belongs to that model.

Carson Tract Houses

Many homes around Carson, Gardena and Bellflower were built with prefab units and framed chases. That is the work we set the truck up for.

Parts Named in Writing

Reports list each part by name and model, so you or the next owner can see what was found and what went in.

Prices on Paper

Set prices are stated up front, and anything else is written after we look. You decide what to fix and when.

Call (323) 524-3947